News Headlines

Sat. Jun 5th 2010
FREE CLEAN UP DAY

WE WILL HAVE A FREE CLEAN UP DAY DUMPER AT THE FIRE STATION JUNE 19,2010 FROM 8 AM TO 4 PM. YOU CAN THROW AWAY HINGS YOU CAN ...

Read more »


Thu. Feb 4th 2010
New Fire Truck Grant

GOOD NEWS WE HAVE BEEN AWARDED TWO NEW FEDERAL GRANTS. THE FIRST ONE IS FOR $200,000.00 FOR A NEW TANKER AND THE SECOND GRANT...

Read more »


Thu. Jan 21st 2010
New Rescue Tools

The New Rescue Tools are in and are now in service on Engine 1. We have gotten in all the equipment this is a new cutter,spre...

Read more »

Apparatus Gallery
Newsletter Subscription

Stay up to date!
Subscribe to our Newsletter.


Enter Your Email Address:



Contact Information

Winterboro Volunteer Fire and Rescue
p.o. box 24
Alpine, AL  35014

Non-Emergency:
256-362-0200

Emergency:
911

Contact Us

Member Login

Username:


Password:




Links

Firefighter down memorial page


Alabama Fire College


AAVFD




 Fire Glossary
 Print this page

Search:

Click a letter to view all entries that begin with that letter:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Page: | 1 | 2 |

Call Fighter
Call firefighters respond as needed on a part time basis to all types of emergencies. Call firefighters train with their local engine companies in their districts. Call firefighters are utilized in three different ways. First Responder call firefighter units are those units that are staffed entirely by paid call firefighters. These firefighters respond to all emergency incidents within their jurisdictional areas and are supported by full-time companies from adjoining jurisdictions. "Supplemental" call firefighter units are those units that staff a second engine company from a station that is also staffed by a full-time company. These units respond to all multi-unit responses in their district and cover the station when the career companies are committed. "Augmentation" call firefighters are assigned to an existing career company and respond directly to the scene to augment that company's staffing.


Cellar fire
Cellar fires are difficult to attack directly because firefighters have to pass through the hot gasses and smoke accumulated on the cellar's ceiling to gain access to the cellar space. Cellars typically do not have good emergency egress points, adding to the danger.


Cellar pipe
Cellar Nozzle. A distributing type nozzle that is inserted through an opening in the floor and into the space below, typically a basement or cellar. The nozzle directs a broken stream horizontally, either extinguishing or controlling the fire enough to allow a direct attack to be safely made. Can also be used on top of other containers.


CFA 3-Thread
A type of coupling used by the CFA, it is used mainly on the australian 64mm hose, it provides a very secure coupling, obviously the threading of the coupling is repeated 3 times, it is non-hemaphoradite.


Charged line
Fire hose under pressure from the pump at the engine.


Check valve
See backflow preventer


Chimney fire
Fast and intense fire in a chimney flue in which accumulated creosote and other combustion byproducts ignite.


Class A, B, C, D, K
Classes of fire extinguisher and corresponding type of fire they extinguish.


Closed area
An area in which specified activities or entry are temporarily restricted to reduce risk of human-caused fires.


Closed-circuit SCBA
See SCBA.


Closet hook
Pike pole under 5 ft long


Closet ladder
See Attic ladder.


Closure
Legal restriction, but not necessarily elimination, of specified activities such as smoking, camping, or entry that might cause fires in a given area.


CO2 extinguisher
Fire extinguisher that releases carbon dioxide gas to smother and cool a fire, such as a flammable liquid.


Cockloft
Structural space above ceiling and below rafters, often connecting adjacent occupancies and permitting fire to spread laterally, often unseen.


Cold trailing
A method of controlling a partly dead fire edge by carefully inspecting and feeling with the hand for heat to detect any fire, digging out every live spot, and trenching any live edge.


Collapse zone
The area around a structure that would contain debris if the building were to collapse.


Combination nozzle
A low pressure Fog Nozzle (usually 120 to 150 lbf/inē or 820 to 1030 [[kilopascal|kPa)) that can be adjusted to produce a near straight stream. Also commonly referred to as a Taskforce Tip (TFT).


Company
Two or more firefighters organized as a team, led by a fire officer, and equipped to perform certain operational functions. Compare with platoon and unit.


Compartment Fire
An Isolated" fire or a fire which is "boxed in" or "closed off" from the rest of the structure. An example of this is a fire in a room where all the windows and doors are closed preventing the fire from spreading to other rooms.





Recent Calls

Sat. Nov 1st 2008
Fire Calls for Nov.1

The Fire Department had a busy day starting with a morning house fire on Church Rd.Tthe home was fully involved upon arrival ...

Read more »


Mon. Jun 16th 2008
Mobile home fire

Dispatched to a mobile home fire at 1034 Reynolds Mills Rd. In Alpine.Upon arrival of first in engine the mobile home was ful...

Read more »


Sun. Mar 2nd 2008
woods fire

We responded to a woods fire on Lawler Cir. at 4 p.m. the fire was started by a train near the railroad. Alabama Forestry and...

Read more »

Upcoming Events

Every 2nd Tue. 7:00pm
Fire Department Meeting

Picture Gallery
Search Our Site

Search:



2010 Call Volume
  Fire EMS
January    
February    
March    
April    
May    
June    
July    
August    
September    
October    
November    
December    
Total 00

View Call Volume History

Visitor Poll

Would you buy an address sign for your home if we sold them for a fundraiser?



Birthdays for September

No birthdays for this month.


YourFirstDue.com Managed web hosting for Fire/EMS



Login



Copyright © 2006-2010. YourFirstDue Inc.. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Content on this web site is supplied by Winterboro Volunteer Fire and Rescue. YourFirstDue Inc. cannot be held responsible or liable for any content, text, pictures, or any other media found on this web site. Maintained by the members and staff of Winterboro Volunteer Fire and Rescue.

This site has been
viewed 124,303 times.